Piloting no-dig lead pipe detection technologies: lessons learned from the field
Failed tests aren’t failures. They’re answers. Sometimes the best path is the one you’re already on. A recent pilot study where no-dig technologies could not accurately find lead showed how important it is to test technologies on specific systems before deploying them large scale.
As utilities work to remove lead service lines (LSLs) from their water systems, there's one crucial question they need to answer first: where are the lead pipes actually located? Developing practical, field-tested solutions that identify unknown pipe materials with minimal resident disruption is essential for delivering a smoother, faster, and more reliable program. DC Water partnered with the Lead Free Group, a joint venture between CDM Smith and Ramboll, to pilot no-dig alternatives to test pitting that could support their mission to identify and replace lead pipes.
Bridging the gap: innovation and practical results
In many communities, identifying LSLs still depends on outdated records. Predictive modeling and digital inventories help narrow the search, but they require accurate field data. Field verifications can be intrusive, costly, and coordination-heavy for utilities and residents alike.
Conditions vary widely across communities. Factors like infrastructure age and local or state building regulations all play a role, so a method that works in one distribution system may not work for another. That's why DC Water pilot tested detection technologies against traditional and reliable test pit methods under real-world urban conditions. The goal: determine the best mix of approaches to reduce unknowns.
How did they do it?
The team tested two no-dig detection technologies at 43 homes: Technology 1 uses external ground probes, and Technology 2 inserts a probe into the pipe at the water meter. Both tools detect pipe materials through electrical properties. Test pits on the private and public sides of each property were used to confirm results using the industry-standard method of excavation.
The pilot assessed each detection technology using five main criteria: accuracy, reliability, ease of deployment, labor required and cost. Accuracy was key. Could the tool consistently and correctly identify pipe materials as reliably as test pitting? The team also looked at why a tool might fail (e.g., plumbing or soil conditions), how much effort it required compared to a test pit, and whether it could deliver cost savings over test pitting.
Technology 1's method involved placing electrodes along the service line to measure conductivity, with reports delivered in 72 hours. This platform is still in the pilot phase.
Technology 2 used probes inserted at the water meter to gather real-time data, with near-instant reports. This platform is commercially available. For this pilot, two different style probes were used at different locations depending on the pipe configuration.
Ultimately, 43 properties were selected for testing; however, only 38 properties were verified with test pits due to limited customer participation at five of the tested properties. Test pits were excavated at two locations: a 36–48 inch hole at the water meter pit and an 18–24 inch hole at the property line.
Since neither technology had been proven in DC Water's system and results hadn't yet been confirmed through test pitting immediately after pilot testing, DC Water provided filters to all properties as a precaution.
Pipe access
A key challenge with physical service line identification is obtaining access to the pipe. In the test area, a typical service connection includes a meter housed within a buffalo box, connected to a riser that leads to the service line (Figure 1). Service lines in the test area ranged from ¾-inch to 1-inch in diameter.
Overall, Technology 1 tested both the private (meter to house) and public (main to meter) service lines at 40 of the 43 sites, while Technology 2 was able to test 24 public-side and 29 private-side service lines. The Technology 1 system only needed direct access to the water meter and was unable to test service lines at three of 43 sites due to obstructed or inaccessible meter pits.
In contrast, access challenges had a greater impact on Technology 2 since its probe needed to be inserted directly into the pipe for testing. Technology 2 could not be used at six properties due to obstructed or inaccessible meter pits, meters in poor condition that posed a risk of damage if removed, pipes that were crimped or severely corroded, or severe bends that the probe could not navigate. An additional five private-side and 10 public-side service lines could not be tested with Technology 2 for the same reasons although it was able to test and provide results for the other side of the service line. During testing, previously unknown ½-inch check valves were discovered at two properties, and one property had an older meter type that DC Water was not aware of and therefore could not be tested (Figure 2). Some meter risers were only ½-inch, which made them challenging for Technology 2 to navigate through. Two sites withdrew from Technology 2 testing due to the need for a water shutoff. No material results were provided for these locations.
Figure 2 Examples of Challenging Plumbing Configurations Encountered
Finding lead service lines
The most critical measure of any service line identification technology is accuracy: can it reliably detect lead pipes? The last thing any public utility wants to do is label a lead pipe as a non-lead material and not offer a replacement at that address or provide a false sense of security to the residents.
Test pits followed the testing of the new technologies to check the accuracy of the technologies in DC Water's system. Test pits could determine the materials at 38 properties, including at some properties the pilot technologies could not access. The test pits found that 27 properties had LSLs: 24 on the private side, 20 on the public side. Of the properties where the technologies provided results, they incorrectly identified many of the lead lines found via test pits as "non lead." Figure 3 summarizes the service line materials identified with Technology 1 and Technology 2 compared with the test pit results.
Out of the properties where test pits found lead, Technology 1 correctly identified 1 of the 22 private-side lead pipes and 4 of the 20 public-side lead pipes it tested. Technology 2 failed to identify any of the 16 private-side or 10 public-side lead pipes it tested. For the remaining locations where test pits found lead, the technologies could not access the pipes and therefore did not provide results. The lead swab Technology 2 used as secondary confirmation also returned no lead results.
Figure 3: Pipe Material Identified by Each Technology at Sites Where Lead Pipes were Found with Test Pits
Note: This chart only shows where test pits found lead. It does not include the properties where the test pits did not find lead.
The performance of both of these technologies raised questions about their accuracy in DC Water's system. Both technologies performed well below what's needed for reliable material identification.
Technology 2 faced plumbing configuration challenges that may have compromised its effectiveness. Some meter risers contained unexpected ½-inch piping between the meter and service line, creating bottlenecks the probe may have struggled to pass through with the equipment Technology 2 provided for the pilot. Technology 2 reported many lines were ½-inch based on their inspections, but test pit measurements reported the service lines were ¾-inch to 1-inch.
To address the plumbing configuration issues, the team analyzed results where Technology 2 reported inspection lengths exceeding 4.5 feet, where the probe would be past the riser and within the service line itself. Even then, Technology 2 failed to identify any lead pipes. The tool reported inspecting between 4.6 and 20 feet at 13 of 16 private-side lead pipes and between 4.6 and 11 feet at six of 10 public-side lead pipes. None of them resulted in a determination of "lead" from the Technology 2 tools used in this pilot.
These results highlight the importance of testing technologies in context: what works for one utility may not work for another. The results of this pilot are specific to DC Water's distribution system. In other systems, these technologies may perform more accurately, and Technology 2 may be able to access a greater number of service lines to categorize materials. However, the configuration and size of the piping in DC clearly limited the effectiveness of Technology 2 in this pilot. The chart below shows why DC ultimately decided to continue using test pits for the time being.
Factor
Test Pit (Current method)
Technology 1
Technology 2
Utility Considerations
Identification method
Visual
Electrical
Electrical (Probe) and Chemical (Swab)
Cost per address in pilot (average)
$1,700 to $2,4001
$6501
$2,000 1, 2
Onsite time (minutes, average)
180 to 3603
91
51
Accuracy of LSL identification in DC water's system
High
Low
Low
Impact on Residents and the Community
Level of coordination with resident
High
Low
Medium
Water service impacted
Yes
No
Yes
Service line disturbance
Yes
No
Yes
Traffic flow disturbance
Yes
No
Yes
Restoration Required
Yes
No
Yes
Note: Cost in 2024 dollars. Based on costs to conduct the small pilot study. Costs to implement in other areas will vary by number of homes surveyed and local conditions. Based on interviews with Lead Free DC construction inspectors.
Putting homeowners first
Earning residents' trust is essential when requesting access to perform work on private property. Protective measures were also a top priority. To maintain confidence and safety, every household received NSF 53/42 certified filters and flushing instructions to make sure drinking water remained safe throughout the process and afterwards. Once a lead pipe was identified, crews took steps to remove the pipe as soon as practical to help safeguard water quality, and the team worked closely with residents to minimize the time between identifying an LSL and replacing it.
Efficiency and clarity guided every stage of this pilot
Prior to the field work:
The team focused pilot sites in areas with active test pit and LSL replacement contracts to minimize delays in starting verification work and replacements.
Households benefited from clear timelines and the peace of mind that replacement would follow quickly.
During the field work:
The team kept constant communication with the residents during the testing process by engaging them at the start of testing and walking them through the process.
Within a few weeks after the field work:
Crews started test pit verifications and replacements to identify and remove LSLs as soon as practical.
The Lead Free Group shared key takeaways from the pilot to refine processes for future testing of alternate identification methods.
The essential role of test pits
While new detection tools show promise in many systems, DC Water's pilot highlighted that there is no one-size-fits-all approach to getting the lead out—each utility has unique needs. Urban systems are often complicated, full of undocumented repairs and pipe configurations that these new detection methods cannot accommodate. In DC Water's case, test pits out-perform the no-dig technologies and provide the confidence to act on solid data, protect public health, and focus resources where they'll have the greatest impact. DC Water plans to continue to pilot new technologies and reduce the number of test pits needed for completing the service line inventory and removing all LSLs in the system.
When you're ready to apply this thinking, our experts can help.
Sandy Kutzing
Environmental Engineer
Sandy is CDM Smith's top strategist in the fight against lead in drinking water, optimizing corrosion control treatment and establishing lead service line replacement programs across the United States.
Javier Locsin
Environmental Engineer
Javier has broad experience in water and wastewater treatment, regulatory compliance, asset reliability and water policy.
What do water systems need to know about lead testing in schools and child care facilities under the LCRI? We asked environmental health expert Davida Judelson, MPH, to break it down.
As part of the Lead and Copper Rule Improvements (LCRI), water utilities are required to communicate with residents and businesses more than ever before about lead in drinking water. We’ve compiled four best practices to effectively communicate with customers.
Is your utility ready for the LCRI? Lessons from Illinois's early experience
Illinois utilities have been operating under stricter lead regulations since 2022, and Chicago's former water commissioner, Andrea Cheng, PhD, PE, shares lessons on navigating new sampling requirements, boosting resident engagement, and coordinating complex inventory efforts.